Tuesday, December 20, 2016

Tank Trouble Tuesday

Our TankCam and PetroScope services are frequently utilized for remote video inspections of older tanks, but we also inspect brand new tanks.

Tank inspections after construction, but prior to the first fuel drop, verify that no tools or landscaping/ construction/ backfill materials are left behind in the tank. Inspections also check for anomalies in the tank walls, changes in overall tank shape, and anything else that may have gone wrong, like the interstitial brine leak below.

For more details on inspections prior to an initial fuel drop, check out a case study from Tanknology Australia.

Watch for more “tank troubles” Tuesdays on our social media pages.

TankCam is patent pending.


Tuesday, December 13, 2016

Tank Trouble Tuesday

The statistics from the EPA’s recent study on diesel corrosion are staggering, and the video footage is just as striking. 

This week’s #TankTroubleTuesday features a GIF from that study’s fieldwork of severe corrosion found with TankCam in a riser for a ULSD tank.

The corrosion was even too severe for the TankCam to enter through this riser, noticeable as scraped off corrosion nodules fall into view.

Watch for more “tank troubles” Tuesdays on our Facebook, Twitter, LinkedIn, and blog pages, or at #TankTroubleTuesday.


TankCam is patent pending.



Tuesday, December 6, 2016

Tank Trouble Tuesday

Tanknology is excited to launch our new social media series “Tank Trouble Tuesday.”
We will feature some of our most interesting findings in tanks around the world from footage captured by our Petroscope® and TankCam® video inspection services.

Watch for more “tank troubles” Tuesdays on our Facebook, Twitter, LinkedIn, and blog pages, or atO#TankTroubleTuesday. 

TankCam is patent pending.

                 


Thursday, October 13, 2016

Headed to next week's NACS Show? Visit us -- and see actual video from the EPA's Diesel Corrosion Study


Corrosion in diesel USTs has become a hot topic since the EPA issued the report in July showing that 83% of tank systems in the US contain moderate to severe levels of corrosion. 

Visit us at PEI at the NACS Show in Atlanta next week -- Booth # 5115 in the Fuel Equipment and Services Hall -- and see actual video from that study!

We performed the field work for that EPA study, and have hours of video and hundreds of photos, showing just how bad this corrosion can become.

Our Brad Hoffman, Vice President of R&D, and the leader of this project for Tanknology, has said, "I have never in my life seen corrosion of this magnitude in a fueling system."

Stop by and see us in Atlanta -- and take a look for yourself.

For more information about the corrosion problem so prevalent in diesel UST systems, visit this page on our website.


To learn more about our TankCam Remote Video Inspection Service, which captured all the video for this study -- or any of our tank inspection or testing services, visit our website or call us at 1-800-964-1250.



To sign up for automatic notifications of updates to our blog, click on the blue "Follow" button on the right.

Wednesday, October 5, 2016

The inside story on field work performed for the EPA's recent study on Diesel UST Corrosion

The EPA's recent report on corrosion levels found in diesel underground storage tank (UST) systems has become a major topic of conversation and concern across the retail and commercial fueling markets.

Moderate-to-severe corrosion was found in 83 percent of UST systems containing Ultra Low Sulfur Diesel (ULSD). Of the tanks exhibiting the corrosion, 75 percent of the owner/operators did not know it was happening.

Our team at Tanknology conducted the field work for this study, under the direction of Brad Hoffman, Tanknology's Vice President of R&D.

In the current issue of Fuel Marketer News, Brad describes the field work his team conducted for this project. The internal tank video images were captured using Tanknology's TankCam(TM) Remote Video Inspection Service. Brad said the images are unlike anything he's ever seen.

"I have been an engineer in the petroleum industry for my entire career, first with Exxon and for the last 23 years with Tanknology," Brad
said. "I have never in my life seen corrosion of this magnitude in a fueling system."

In the Fuel Marketer News article, Brad discusses the findings, what operators can do to investigate whether it's a problem -- and what they can do about it.

You can find that article here.

To see more images like you see here, which were captured during the survey, or learn more about the issue of corrosion in UST systems, visit the Diesel Corrosion page on our website, where you can also find a copy of the EPA's report and other helpful resources.

For more information about our TankCam remote video inspection service, or any of our tank inspection or testing services, visit our website or call us at 1-800-964-1250.

To sign up for automatic notifications of any updates to our blog, click on the blue "Follow" button on the right.

Thursday, August 25, 2016

Tanknology Regulatory Insights Featured in Fuel Marketer News Vender View

Today's edition of the  Fuel Marketer News Vendor View column featured some new insights by Tanknology's Kevin Keegan on topical issues related to the new EPA UST regulations.

Specifically, Kevin addresses under-dispenser secondary containment testing and whether the OPW FlexWorks system meets a key standard.

Related to sump inspection requirements in the 2015 revision to the regulations, Kevin also discusses an approach that could potentially offer marketers a significant cost savings strategy.

You can read Kevin's thoughts on these hot regulatory topics, here at Fuel Marketer News online

To sign up for automatic notifications of any updates to our blog, click on the blue "Join this Site" button to the right.

Tuesday, August 2, 2016

EPA Study: 83% of diesel tanks have moderate to severe levels of corrosion

The EPA has released the results of the largest survey to-date on corrosion levels in underground storage tanks (USTs) containing diesel fuel -- and the results are staggering.

The research showed that 83 percent of the USTs studied exhibit moderate to severe corrosion.

Worse, only 25 percent of the owners of those tanks with corrosion were aware of it prior to the study.

That, according to Carolyn Hoskinson, Director of the EPA’s Office of Underground Storage Tanks (OUST) is troubling – because that corrosion “could result in an increased chance of releases of fuel to the environment and subsequent groundwater contamination.” Every UST operator’s nightmare.

The results of the survey, conducted by the renowned Battelle research institute, were not a surprise to us at Tanknology, as we performed all the fieldwork for this study as a partner of Battelle. Among other services, our TankCam® remote video inspection service provided the high-resolution images used in the analysis and the EPA’s final report.

In addition to the prevalence of corrosion in the diesel tanks inspected and the lack of awareness by owners, some ‘key takeaways’ the EPA identified include:
  • Severe corrosion is not limited to the tanks themselves, but also prevalent in all the metal components of the fueling system. This is true in steel as well as fiberglass tanks.
  • The condition is widespread – affecting diesel fueling systems in multiple regions of the country.
  • There are approximately 100,000 federally-regulated diesel tanks in use in the US, according to PEI.
  • Ethanol was present in 90 percent of the 42 tanks sampled, “suggesting cross contamination of diesel fuel with ethanol is likely the norm.”
  • Tanknology technicians collected fuel samples from each tank system in the study and Battelle's testing against several fuel specifications and guidelines indicated that "many UST systems may be storing fuel that is less clean and dry" than those standards intend.
  • The presence of particulates and water in the fuel were “closest to being statistically predictive factors for metal corrosion,” though the EPA said the findings don’t necessarily signal causation.
What EPA OUST recommends:
  • Visual inspection of fuel filters and tank system access points for signs of corrosion.
  • Utilizing a UST service company (such as Tanknology) to further evaluate the extent of corrosion in the tank system. Tanknology could employ the same TankCam remote visual inspection service used in the EPA study to provide a clear look inside your tank system, capturing potential corrosion on video for further assessment.
  • Repairing or replacing equipment to ensure proper functionality.
A PDF copy of the EPA study can be viewed and downloaded here, from our website, in the section, 'Learn More.'

For more information about our TankCam remote video inspection service, or any of our tank inspection or testing services, visit our website or call us at 1-800-964-1250.