Friday, January 31, 2014

See us at the California CUPA Forum in San Francisco

If you are taking in the California CUPA Forum Annual Training Conference next week at the Hyatt Regency San Francisco Airport, you’ll want to be sure to take in a session at 10:00 AM on Wednesday, titled, Storage Tank Maintenance for Today’s New Fuels.

Video still of blistering and exposed fibers in a fiberglass UST
Tanknology’s Brad Hoffman, VP of Engineering and R&D, will be a speaker in the session, along with Wayne Geyer and Lorri Grainawi of the Steel Tank Institute.
 
Brad will be discussing PEI’s RP900 recommended UST Inspection and Maintenance practices and RP1200 protocol for Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities; UST cleaning and removal methods; and sharing some actual video results from Tanknology’s TankCam® and PetroScope® video inspections of actual in-use USTs. Brad first shared some of these video clips at the National Tanks Conference in Denver last fall, and will be adding to them with new clips in this presentation at Cal-CUPA.

As a UST operator, it’s a session you won’t want to miss – 10 AM Wednesday in the Regency A room.

Be sure to also stop by and see us on the exhibit floor, where we will also have actual tank inspection video that you can view up close and personal. You will find us in Booth #30.

Thursday, January 9, 2014

Three Tanknology executives named to PEI Committees

With the New Year came a new President of the Petroleum Equipment Institute (PEI). Phil Farrell, President of Double Check Company of Kansas City, MO, assumed the leadership of the industry’s largest association of companies that manufacture, distribute and service petroleum equipment.

Double Check Company is a strong partner of Tanknology, as one of our Master Alliance Partners (MAPs) in the U.S. We congratulate Phil on this new leadership role with PEI and know that the association is in good hands.

One of Phil’s first acts was to name members to PEI’s 22 various committees. Three Tanknology executives were among those named this week:
  • Brian Derge, Vice President of the Eastern Division, is a member of the Overfill, Release Detection and Release Prevention Equipment Testing Committee.
  • Brad Hoffman, Vice President of Research & Development is a member of the UST System Inspection and Maintenance Committee.
  • Eddie Campbell, Regional Manager of the Southeastern US, is a member of the Safety Committee.
We are pleased to have the opportunity for our executives to participate with PEI in these important industry committees. 

Friday, October 11, 2013

Visit us at the NACS Show in Atlanta and see some tank inspection videos you won’t want to miss

Be sure to stop by and see us at the PEI at the NACS Show in Atlanta, starting Sunday.

You’ll find us in Booth #4622 in the Fuel Equipment & Services Section.

On display, we will have a new video, with the same clips our Vice President of R&D Brad Hoffman just presented at the National Tanks Conference last month in Denver. The clips exhibit the exceptional insights provided by our TankCam and PetroScope Video Inspection Services – with a series of high-definition clips showing some astonishing details of the condition inside several USTs we’ve inspected. You won’t want to miss seeing this.

If you didn’t see these clips in Brad’s presentation at the National Tanks Conference, don’t miss this second chance. If you did see them, you need to see them in the high definition clarity provided by these technologies.

While you’re visiting, be sure to sign up to win an iPad. We will be giving one away again this year to a lucky winner who stops by to visit and enters the drawing.

We hope to see you in Atlanta!

Wednesday, October 2, 2013

Aging tank population in Arizona makes headlines; But is the focus on age the right focus?

Beneath the ground at more than half of the gas stations in the State of Arizona, sit “old, rotting and potentially leaking fuel storage tanks,” according to a recent CBS-5 TV 5-Investigates report.

Quoting an audit performed by the state Auditor General’s Office, the Phoenix CBS-TV affiliate reports that nearly 1,000 USTs in the state are older than their expected 30-year lifespan and nearly 3,000 are approaching it within the next decade.

Click here to watch the CBS-5 Segment
Steve Brittle, the President of Arizona-based environmental advocacy group, “Don’t Waste Arizona,” says in the story that these thousands of tanks are at, or on the verge of, the end of their 30-year life expectancy. Generally, Brittle says, the tanks “need to be replaced at that point.”

“In our experience, that’s definitely not a given,” said Allen Porter, President and CEO of Tanknology.

“We have a lot of customers across the country with tanks in this age range. Most of them are wrestling with how and when to upgrade and replace tanks as they approach the 25-year mark. There are a number of factors that influence how a tank degrades over the years and age is just one of them.”

Porter said the company has seen many tanks in the 25- to 30-year age range that are in just fine condition.  “We’ve also seen tanks half that age that are in worse condition. It’s very site and situation specific.”
Still photo capture from actual TankCam video

In response to the growing need to understand the condition of aging tanks, Tanknology worked with several large nationwide service station operators in the development of its TankCam® Remote Tank Inspection system. The TankCam service involves putting a high resolution, lighted camera inside the tank, providing the ability to closely survey the conditions so that an operator can understand what’s happening inside the tank and then prioritize upgrade programs.

“Obviously operators want to focus their upgrade plans on the tanks in the poorest condition,” Porter said. “Our TankCam service provides them a very economical way to get a good clear look at what’s going on in that tank so that they can make informed decisions. In many cases, they are learning that just because a tank is 25-years old, it’s not necessarily in need of replacement. That allows them to turn their attention elsewhere, to the tanks which we help them see are at a higher risk of leaking.”

Tanknology’s TankCam® Remote Inspection service is available nationwide.  Inspections are quick and tanks typically do not have to be taken out of service during the process. More information and examples of actual video from inside a tank can be found on our website.

Monday, September 9, 2013

Don't miss Tanknology's Brad Hoffman in his presentation at the National Tanks Conference next week in Denver

Next week at the National Tanks Conference in Denver, Brad Hoffman, Tanknology’s Vice President of Engineering and R&D, will provide a presentation and participate in a panel discussion on UST management and compatibility related issues. It’s a session any tank operator won’t want to miss.

According to Brad, his focus in this session will be on helping operators with the management, maintenance and evolving compatibility issues in their aging tank population.

“Many operators upgraded tank sites to conform with the initial EPA regulations in the late 80s,” he said. “Many of those tanks have been in the ground for around 25 years now – or more. As they look to evaluate their condition, and prioritize replacement programs, many are struggling with how best to do that.”

“Age is the most obvious basis for that prioritization,” he said. “But that’s not necessarily the most prudent approach.”

Brad will address in this session how to prioritize tank management and replacement programs based on actual need, rather than simply age.

“In our experience, operators could be spending their upgrade dollars most effectively by understanding the actual conditions of those tanks and prioritizing on that basis. Just because a tank is x-years old, doesn’t mean it needs to be addressed earlier than one which is several years younger,” he said. “The specific conditions inside those tanks really matters.”

This very issue is exacerbated by the unusually high level of metal corrosion and tank lining and structural issues that have become a growing problem of late in some aging tank systems.

“These are all factors in managing the risk and best practices of a tank population,” Brad said. “We’ll do our best to tackle these issues in our session and address what operators can do to understand specific tank conditions before automatically looking at replacement.”

The session is titled, Out of Sight, Out of Mind: How to Evaluate UST Usefulness, Management and Compatibility, and will take place in the Sheraton Denver Downtown Plaza Ballroom E on Wednesday, Sept. 18, from 8:00 to 9:30 AM.

Brad will be also be available for individual conversations at Tanknology’s booth in the exhibitor area – Booth 300 – on and off throughout the conference.

Tuesday, May 14, 2013

SP001 Inspections for ASTs: What you need to know

If your organization operates shop-fabricated or field-erected aboveground storage tanks (ASTs), you’re likely at least somewhat aware of the Spill Prevention, Control and Countermeasure (SPCC) requirements for regular inspections of these tanks. If you have ASTs that are required to conform to these regulations, there is an article in this quarter’s edition of the PEI Journal that you should read.

Titled, Integrity Testing Shop-Fabricated Aboveground Storage Tanks, the article by Alex Ralston, POE, provides an excellent summary of the inspection requirements and procedures required by STI SP001, which is the Standard for the Inspection of Aboveground Storage Tanks.

The SP001 standard applies to portable containers, shop-fabricated tanks and field-erected tanks up a maximum shell height of 50 feet, and a maximum diameter of 30 feet. In the article, Ralston summarizes the essential elements of this standard: 
"The STI SP001 standard is not a tightness test similar to those performed on underground tanks. The standard measures construction integrity; compliance with fire codes, building codes, industry standards and OSHA standards; and the integrity of the thickness of the metal tank shell as compared to the original tank shell thickness. That last requirement is essential. The shell thickness determines the suitability of the tank for continued service – specifically, whether the tank should continue in service or be taken out of service for repair or replacement. The inspection also sets the date of the next formal inspection."
The article goes on to include a detailed summary of what a certified inspector looks for in a SP001 inspection. It’s an excellent read if this is an area of concern for your fueling operation.

Tanknology provides SP001 inspections and testing. If you would like to set up an inspection program, review your existing approach, or learn more about our AST related services, email us at info@tanknology.com or call us at 1-800-964-1250.

Wednesday, May 1, 2013

Update on research targeting corrosion in ULSD systems

A significant topic in the petroleum storage and dispensing world in recent years has been the extreme rate of corrosion being experienced in some UST systems containing ultra-low sulfur diesel (ULSD). As early as 2008, this phenomenon was observed and by 2011 major industry organizations were in high gear in search of answers.

These organizations, which form the Clean Diesel Fuel Alliance (CDFA), awarded to the Battelle Memorial Institute with the support of Tanknology a research project intended to gain an understanding of what is causing the corrosion so that they might create a solution.

Battelle and Tanknology have now completed this initial project and the detailed findings are being reported in the current issue of the PEI Journal.

As a result of the sampling and analysis program in this study, the ultimate hypothesis was that the corrosion is likely due to the dispersal of acetic acid through the USTs.  This acid is likely produced by Acetobacter bacteria feeding on low levels of ethanol contamination. Dispersed into the humid vapor space and by disturbances during fuel deliveries, the acetic acid is deposited throughout the system. This results in a cycle of wetting and drying of the equipment, concentrating the acetic acid on the metal equipment and corroding it severely and rapidly. (The fill riser and STP photos to the right illustrate the severity of ULSD corrosion.)

But where is the ethanol contamination coming from? Initial study points to two possibilities: From switch loading or from a gasoline tank ventilation system that is manifolded with the diesel tank.

While this initial project provided an important step in possibly identifying the root cause of this rapid rate of corrosion, it did not provide enough certainty to justify changing the ULSD fuel distribution system.

The CDFA task force is now pursuing a next-level research project. In this advanced project, the hypothesis of the initial research will be further studied in order to prove or disprove it, as well as to provide a basis for alternative hypotheses if necessary and to identify the leading factors promoting the corrosive environment of ULSD systems.

According to Brad Hoffman, Tanknology’s lead scientist on the initial study, there is a clear sense of urgency in the work of the task force. “Corrosion at this rate of speed is very concerning,” Hoffman said. “So everyone is very anxious to understand why it’s happening and what needs to be done to stop it. At this point, we have what appear to be strong indications of what’s going on, but those need to be proven out so that corrective measures can be designed to mitigate this problem.”

So what can be done to minimize the potential for such corrosion in the meantime? According to Hoffman, “Until the absolute cause and a cure are identified, we recommend that operators keep their tank bottoms as absolutely free of water as possible. This is an important practice for any tank, but is particularly true of diesel tanks. Water is the enemy of fuel – especially diesel – in a UST.”