Tuesday, May 8, 2012

April Showers Bring...


There is an old saying that April showers bring May flowers. For station operators, the season can also bring a whole set of challenges. Often, the winter thaw and rainy spring can result in containment sumps and spill buckets full of water. There are many possibilities for the causes, ranging from the combination of high groundwater and deteriorated or improperly sealed piping penetrations, to lids with missing gaskets, or that have been re-installed without the proper clamps or bolts tightened properly.
 
Containment sumps are designed to be watertight and kept dry, so that there is sufficient capacity to retain product in the event of a release from the piping system. The danger of full sumps highlights several major issues. First, standing water is a primary cause for corrosion to submersible motors and other metallic piping components in sumps.  This poses not only an environmental impact, but also a potential economic impact (think 50 gallons of water into 10,000 gallons of ethanol blend)  Second, if the water is entering from piping penetrations during times of high groundwater, then product can just as easily escape from the same points when the water table is lower. Also, because water is heavier than most fuel products, if the sump is full of water, then any product released would float to the top, and could overflow out to uncontained backfill surrounding the sump, causing a direct and immediate environmental impact.

There’s another old saying that an ounce of prevention is worth a pound of cure. Now is a great time to develop a routine inspection plan for your sites based on the Federal A,B,C operator program if you haven't done so already. Take some time to open your sumps and inspect their condition - all it takes is a couple of minutes. If they’re full, take action. Identify the cause, and get them fixed. Constant water removal can be extremely expensive, and actually fixing the problem can be much more cost effective than repeated pump-outs in many cases. Don’t wait for the local inspector to do the inspection for you. Many states are starting to enforce “red tag” authority, prohibiting fuel deliveries until violations are fixed, and secondary containment is a popular discussion topic right now among regulatory agencies.

Tuesday, March 27, 2012

Spill and Overfill Containment - Catching Small Problems Before They Become Major Environmental Releases

There has been a lot of recent discussion regarding the importance of spill and overfill containment buckets.  A recent study conducted in Florida identified that roughly 36% of all UST releases were the result of faulty spill containment buckets - an astounding figure. Link Proposed updates to Federal regulations currently up for discussion will require not only the installation of double walled buckets during new construction and upgrades, but also periodic testing for leaks. We have heard many opinions on the proposed rules as a whole (both positive and negative), but the consensus seems to be that spill containment is a logical place to require updated equipment and periodic testing.

Addressing critical containment equipment with frequent inspections, cleaning, and regular testing can often identify a small pinhole leak before it becomes a cause for delivery prohibition by a local inspector, or worse a major environmental cleanup. Vacuum testing is fast, requires little or no interruption of normal fueling activities, and does not generate any contaminated water, eliminating the need for expensive disposal.

This quick and low-cost test could save an operator tens of thousands of dollars down the road.

Tuesday, January 17, 2012

Is testing the functionality of an automatic tank gauge really important?

The Federal EPA, along with many States have adopted, or are in the process of implementing rules requiring operators to conduct periodic functionality testing of their ATG systems.  There has been some confusion on what is required, and how a functionality test should be performed.

Operators have made a significant investment in either installing or purchasing a site equipped with a tank gauge system, including sophisticated electronic line leak detectors in many cases.  That investment is intended to provide you with important protection against potentially catastrophic environmental problems.  An improperly maintained ATG system can fail to alert you to a tank taking on water, or losing product into the ground – both very costly.  Are you positive that your system is working properly and providing you the protection you are counting on?

There is a common misconception that pushing the red button and seeing “All Functions Normal” or a similar message is sufficient for a functionality test.  This can lead to a false sense of security, as your system may in fact not be working properly.

When choosing a vendor to perform your ATG functionality test or certification, you should make sure that their staff is trained and certified to work on your system, and that they will physically inspect each component, including tank gauge probes, sump and interstitial sensors, and the console itself.  Anyone who simply pushes the red button and tells you that everything is OK isn’t helping you protect yourself.

An ATG functionality test is an inexpensive way to protect your investment, reduce risks associated with a leak that isn’t caught or a costly regulatory violation due to non-compliance.  In most cases this test can be performed with little or no interruption to normal fueling activity.

Tanknology names Brad Walls to new sales role

Brad Walls has been named as the company’s Director of Sales; Central Division.

Brad brings to his new role more than 20 years of senior-level sales, management and operational experience, including industries ranging from environmental equipment, to communications to finance. Walls most recently served as Tanknology’s Director of Sales; Non-Retail Fuels. Prior to joining Tanknology, Brad was the Regional Sales Manager for Great Plains Industries, Inc. (GPI) of Wichita.

Brad's new territory will span from Ohio, west to Kansas, and from North Dakota and Minnesota, south to Missouri and Kentucky. Walls will be based out of our offices in Owatonna, MN., Elgin, IL., and Columbus, OH.  He can reached at (800) 476-4929, or via email at bwalls@tanknology.com.

Tuesday, November 1, 2011

EPA releases proposed changes to UST regs

The Federal EPA has released a long-awaited draft of its proposed changes to nation's UST regulations. It proposes a number of revisions to the technical requirements stipulated in 40 CFR 280, as well as a number of new regulations and changes to the types of sites that are currently deferred from regulation.

Robert Renkes of PEI provided an excellent summary in yesterday's Tulsa Letter. You can read a copy of that here on the PEI website.

Additionally, a copy of the proposed rule and documents summarizing and comparing the existing to proposed regulations can also be found here on the website of the EPA's Office of Underground Storage Tanks (OUST).

The EPA expects the proposed revisions to be printed in the Federal Register this week, which will be followed by 90 days for public comment.

Monday, October 24, 2011

And the iPad winner is. . .

Susan Burkhardt, from Neumayer Equipment Co of St. Louis, is the winner of our iPad 2 Promotion at the 2011 NACS/PEI show in Chicago.

Congratulations, Susan!

Thank you to everyone who stopped by to visit us at this year's show.

Sunday, October 2, 2011

Register to Win an iPad 2!

See us at the NACS/PEI Show in Chicago -- and Register to Win! Booth # 7363